Ximi Elga

LODOX STATSCAN PDF

Emerg Radiol. Dec;13(3) Epub Oct 7. Initial experience with Lodox Statscan imaging system for detecting injuries of the pelvis and. Lodox Statscan is a whole-body, skeletal and soft-tissue, low-dose X-ray scanner with digital enhancement and enlargement capabilities. Ten years ago it was. The two Lodox Statscan machines cost R million in total and form part of the Provincial Department of Health’s R million budget for new.

Author: Samukora Nazuru
Country: Burma
Language: English (Spanish)
Genre: Personal Growth
Published (Last): 23 August 2011
Pages: 218
PDF File Size: 1.85 Mb
ePub File Size: 2.18 Mb
ISBN: 246-7-89082-535-1
Downloads: 35467
Price: Free* [*Free Regsitration Required]
Uploader: Sazahn

A new digital, low-radiation imaging device, the “Lodox Statscan” LSprovides full-body anterior and lateral views based on enhanced linear slot-scanning technology in just over 5 minutes.

A prospective randomized study is warranted to support these data. The Lodox Statscan podox are low-dosage digital radiography equipment designed to specifically meet the needs of forensic pathology as well as emergency centres.

Patients under the age of 16 years were not included.

At our facility, we no longer perform plain radiography for C-spine and head injury, but perform CT scans according to the Canadian rules. LS and CT images of chest injuries, injuries to the thoracolumbar spine, and fractures of the pelvis were compared.

It is particularly useful for detecting bullets, shrapnel, fractures and foreign objects that through other procedures may remain undetected.

  G084SN03 V0 PDF

Search form Search this site. The two Lodox Statscan machines cost R5.

Lodox Statscan Machines for the Forensic Pathology Services (FPS) | Western Cape Government

The machines are able to provide scans of both bone and soft tissue, useful in the diagnosis of a wide range of traumatic injuries. Skip to main content. Compared with figures in the lpdox, LS was more accurate than conventional X-rays. A two-year study conducted at the trauma unit at Groote Schuur Hospital found that the Statscan showed that medical staff members were exposed to significantly lower radiation doses compared to conventional x-ray devices.

We have the first LS in Europe at our facility. Such isolated radiographs, usually obtained by bedside machines, can result in limited, low-quality studies that can adversely affect management.

Uys said that the availability of this new technology and equipment will improve the quality of the service. The images are digital, so they can be transferred across a computer network, rotated and manipulated without loss in quality.

The aim of this study was to compare LS with computed tomographic CT scanning, as the gold standard, to determine the sensitivity of LS investigation in detecting injuries to the chest, thoracolumbar spine, and pelvis from our own experience, and to compare our findings with those of conventional radiography in the literature.

Lodox Statscan Machines for the Forensic Pathology Services (FPS)

Full-body x-rays can be completed in 13 seconds, whilst non-specialised personnel are now able to perform procedures rapidly at a much-reduced risk of radiation exposure. Findings with LS statscaan also compared with those reported for conventional radiography in the literature. Full-body radiography with LS visualizes skeletal, chest, and pelvic pathologies “all-in-one. Communication Email: Vital evidence, previously undetected will assist with criminal proceedings and in some instances assist with the identification of the deceased.

  BRDU MSDS PDF

Lodox – Saving Lives Through Innovative Solutions

ATLS Guidelines recommend single plain radiography of the chest and pelvis as part of the primary survey. We performed a retrospective chart analysis of patients with multiple injuries examined by full-body LS imaging and CT scans between October 1, and October 1, at our facility.

Due to the fact that the body can be scanned and the image displayed within one minute, the Lodox Statscan will bring about less invasive work required on the body as the sratscan of foreign objects, fractures sstatscan shrapnel would be expedited.

There is also no need for x-ray film or cartridges, thereby dramatically reducing operating costs.